Gauge
Display input value on circular scale
- 库:
Simulink / Dashboard
Description
TheGaugeblock displays the connected signal on a circular scale during simulation. You can use theGaugeblock with other Dashboard blocks to build an interactive dashboard of controls and indicators for your model. TheGaugeblock provides an indication of the instantaneous value of the connected signal throughout simulation. You can modify the range of theGaugeblock to fit your data. You can also customize the appearance of theGaugeblock to provide more information about your signal. For example, you can color-code in-specification and out-of-specification ranges.
Connection
Dashboard blocks do not use ports to connect to signals. To connect a signal to a Dashboard block, use theConnectiontable in the block's parameters.
Double-click the block.
Populate the connection table by selecting signals of interest in your model.
Select the check box next to the signal you want to display.
ClickApply.
Limitations
You cannot save the block connections or properties in model files that use the
MDL
format.To save connections and properties, save the model file in the
SLX
format.Dashboard blocks can only connect to real scalar signals.
Dashboard blocks cannot connect to blocks that are commented out.
Dashboard blocks cannot connect to signals inside reference models.
If you turn off logging for a signal connected to a Dashboard block, the model stops sending data from that signal to the block. To view the signal again, reconnect the signal.